AMF Panels in Hyderabad
Automatic Mains Failure (AMF) panels start your diesel generator the moment grid supply fails, transfer the load to the DG once it is up to speed, and hand it back to mains when normal supply returns – then run the generator down on a cooling cycle and shut it off. The whole sequence happens without an operator. Each panel is matched to your DG set and load, built with interlocked switching and tested before despatch.
Request Quote ›
High-Performance AMF Panels
- Automatic DG start on mains failure and stop after mains restoration
- Mains-to-DG changeover with electrical and mechanical interlocking
- Microprocessor AMF controller with LCD display and event log
- Engine protections: low oil pressure, high temperature, overspeed, fail-to-start
- Adjustable start, transfer, retransfer and cooling timers
- Battery charger and DG battery monitoring
- Suitable for single DG sets from small to large ratings
Role of AMF Panels in Standby Power Systems
A standby generator is only useful if it starts when it is needed. An AMF panel constantly monitors the mains supply; when it fails or goes out of limits, the controller cranks the DG set, checks that voltage and frequency are stable, and only then transfers the load.
When the grid returns and stays healthy for a set time, the panel moves the load back to mains and lets the generator run unloaded to cool down before stopping it. Engine protections shut the DG down safely if anything goes wrong, and every event is logged for your maintenance team.
We select the controller, contactors or breakers, and cabling to suit your generator rating and load profile, so the system starts reliably, changes over cleanly and protects your engine for years.
Applications of AMF Panels Across Industries
Our AMF panels bring hands-free standby power to any site that relies on a DG set.
- Hospitals and healthcare facilities
- Apartments, villas and gated communities
- Commercial buildings, offices and banks
- Factories and industrial units
- Telecom sites, data centres and server rooms
- Hotels, schools and institutions

The DG starts, takes the load and shuts down again without anyone being on site.
Built-in engine protections stop the DG safely on low oil pressure, high temperature or overspeed.
Standby power is back within seconds of a mains failure, keeping critical loads running.
Cooling cycles and timed shutdowns avoid unnecessary running hours and engine wear.
LCD display and event log show mains, DG and load status at a glance.
Interlocking ensures mains and generator are never connected together.
Reliable. Efficient. Generator-Ready.
We do not just connect a controller to a generator – we engineer the complete start, transfer and shutdown sequence around your DG set and load. With proven AMF controllers, quality switchgear and full functional testing, your backup power works the first time, every time.